Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 34
Filter
1.
Braz. dent. j ; 35: e24, 2024. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1550094

ABSTRACT

Abstract This study investigated microshear bond strength (µSBS) of two (2) dual-cured resin-luting agents (RelyX™ Ultimate and RelyX™ U200) when photoactivated through varying thicknesses of lithium disilicate, with or without thermal cycling. Discs of IPS e.max Press of 0.5, 1.5, and 2 mm in thickness were obtained. Elastomer molds (3.0 mm in thickness) with four cylinder-shaped orifices 1.0 mm in diameter, were placed onto the ceramic surfaces and filled with resin-luting agents. A Mylar strip, glass plate, and load of 250 grams were placed over the filled mold. The load was removed and the resin-luting agents were photoactivated through the ceramics using a single-peak LED (Radii Plus.) All samples were stored in distilled water at 37oC for 24 h. Half of the samples were subjected to thermal cycling (3,000 cycles; 5ºC and 55ºC). All samples were then submitted to µSBS test using a universal testing machine (Instron 4411) at a crosshead speed of 0.5 mm/min. Data were submitted to three-way ANOVA and Tukey post-hoc test (α=0.05). The mean µSBS at 24 h was significantly higher than after thermal cycling (p<0.05). No statistical difference was found between resin-luting agents (p > 0.05). The mean µSBS for groups photoactivated through 0.5 mm ceramic were significantly higher than 1.5 mm and 2.0 mm (p < 0.05). In conclusion, increased ceramic thicknesses reduced the bond strength of tested resin-luting agents to lithium disilicate. No differences were found between resin-luting agents. Thermal cycling reduced the bond strength of both resin-luting agents.


Resumo: Este estudo investigou a resistência de união ao microcisalhamento (RUµC) de dois (2) agentes de cimentação de resina dual (RelyX™ Ultimate e RelyX™ U200) quando fotoativados através de diferentes espessuras de dissilicato de lítio, com ou sem ciclagem térmica. Discos do IPS e.max Press de 0,5, 1,5 e 2 mm de espessura foram obtidos. Moldes de elastômero (3,0 mm de espessura) com quatro orifícios cilíndricos de 1,0 mm de diâmetro foram colocados sobre as superfícies cerâmicas e preenchidos com agentes de cimentação de resina. Uma tira Mylar, placa de vidro e carga de 250 gramas foram colocadas sobre o molde preenchido. A carga foi removida e os agentes de cimentação resinosos foram fotoativados através da cerâmica usando um LED de pico-único (Radii Plus). Todas as amostras foram armazenadas em água deionizada a 37oC por 24 h. Metade das amostras foi submetida a ciclagem térmica (3.000 ciclos; 5ºC e 55ºC). Todas as amostras foram então submetidas ao teste de RUµC usando uma máquina de teste universal (Instron 4411) com velocidade de 0,5 mm/min. Os dados foram submetidos à Análise de Variância três fatores e ao teste post-hoc de Tukey (α = 0,05). A média de RUµC em 24 h foi significativamente maior do que após a ciclagem térmica (p < 0,05). Não houve diferença estatística entre os cimentos resinosos (p > 0,05). As médias de RUµC para grupos fotoativados através de cerâmica de 0,5 mm foram significativamente maiores do que 1,5 mm e 2,0 mm (p < 0,05). Em conclusão, o aumento da espessura da cerâmica reduziu a resistência de união dos agentes de cimentação resinosos ao dissilicato de lítio. Não foram encontradas diferenças entre os agentes de cimentação resinosos. A ciclagem térmica reduziu a resistência de união de ambos os agentes de cimentação resinosos.

2.
Hematol., Transfus. Cell Ther. (Impr.) ; 45(supl.2): S36-S42, July 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1514185

ABSTRACT

ABSTRACT Introduction: Brazil has many inequities in the healthcare provided nationwide. Therefore, in order to access challenges in treatment, available resources and current practices, to identify barriers in delivering a good quality of care among Brazilian centers treating children and adolescents with Non-Hodgkin Lymphoma (NHL) and to generate a future prospective guideline, a customized online survey was distributed to pediatric hematologists and oncologists across the country. Results: A total of 97 surveys were completed (35% response rate), from 47 cities in all Brazilian regions and 79 units of care, with a median of 1 answer by the center (range 1 - 5). Most respondents work at an institution supported exclusively by public/philanthropic resources (58%), with an average of 5 to 9 new cases/year (49%), and 41% have 4 to 6 oncologists/centers. Additionally, 22% have no easy access to the intensive care unit, 26% have no access to Rasburicase, 28% have no access to Rituximabe as front-line therapy and 41% have unreliable methotrexate monitoring levels. Those differences cannot be explained thoroughly by regional wealth variances, nor by the financing model. Regarding the pathology service, 70% consider having reasonable quality assistance, but the timeframe to deliver diagnosis is satisfactory to 46%. There is no uniform management of care, with the current guideline from the Sociedade Brasileira de Oncologia Pediátrica being adopted by 54 to 59%, depending on the NHL subtype. Conclusion: This study provides insights into the heterogeneity of care among Brazilian centers. Recognizing those diversities will support the design of effective strategies and collaboration nationwide.

3.
Braz. oral res. (Online) ; 37: e065, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439737

ABSTRACT

Abstract The aim of this study was to quantify the force exerted by tandem archwires in a specific system of passive self-ligating bracket. Forty-eight thermo-activated nickel-titanium orthodontic archwires were separated into four groups (n = 12): G1 - two .014" + .014" round archwires; G2 - two .014" + .016" round archwires; G3 - .014" x .025" rectangular archwire; and. G4 - .016" x .022" rectangular archwire. Brackets were fixed onto teeth 1.5 to 2.5 using a device that represented the upper teeth, maintaining an interbracket distance of 6.0 mm. The deflection tests were performed using the structure representative of tooth 1.1 as support on the Instron testing machine at a speed of 2.0 mm/min. The archwires were evaluated at deflections of 0.5 mm, 1.0 mm, and 1.5 mm. The data were analyzed by a generalized linear model, considering values at different deflections as repeated measurements in the same experimental unit (α = 0.5%). At 0.5 mm, higher forces were observed in G2 and G3, which did not differ significantly (p > 0.05). The lowest force was observed in G4 (p < 0.05). At 1.0 mm and 1.5 mm, the highest force was observed in G3, followed by G4 and G2 (p < 0.05). The lowest force was observed in G1 (p < 0.05). In general, tandem archwires (same or different calibers) in a specific passive self-ligating bracket exerted lower force when compared with rectangular archwires.

4.
Braz. dent. j ; 33(5): 55-63, Sep.-Oct. 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1403787

ABSTRACT

Abstract A new device was developed to enable the visualization and measurement of canine angulation while at the same time visualizing and measuring the force transmitted to adjacent teeth. This study aimed to evaluate the mesiodistal tilt angle of the upper canine brackets, the wire deflection, and its effects on adjacent teeth with five different slot designs of upper canines. Wires (0.020" and 0.019" x 0.025") were tested on different five bracket types at five different distal angles. The force applied to adjacent teeth was measured as the angle was increased, and its consequences were observed in the posterior and anterior regions as well. The force tension (gf) was measured in a universal testing machine. Data were submitted to a 3-way ANOVA and Tukey's test (α=0.05). For both arches, regardless of the type of tooth and bracket type, the highest means tension mean values were shown by the 20° angle, followed by the 15°,10°, and 5° angles, which differed statistically among themselves. Overall, for 5°, 10°, and 15° angles, conventional and versatile brackets showed significantly higher force values in all teeth, tip-edge and control brackets showed the lowest. The highest force values were observed in central and lateral incisors with conventional and versatile brackets and on first and second premolar teeth with self-ligating passive and control brackets. Conventional brackets presented the highest forces, tip-edge and control brackets showed the lowest. The teeth that suffered the greatest forces were lateral incisors, and those that suffered the least were second premolars.


Resumo Foi desenvolvido um novo dispositivo para permitir a visualização e medição da angulação canina ao mesmo tempo que se visualiza e mede a força transmitida aos dentes adjacentes. Este estudo avaliou o ângulo de inclinação mesiodistal dos braquetes caninos superiores, a deflexão do fio, e os seus efeitos nos dentes adjacentes com cinco diferentes desenhos de ranhuras dos caninos superiores. Os fios (0,020" e 0,019" x 0,025") foram testados em cinco diferentes tipos de braquetes e ângulos distais. A força aplicada aos dentes adjacentes foi medida a medida que o ângulo era aumentado, e as suas consequências foram observadas também nas regiões posterior e anterior. A tensão da força (gf) foi medida em uma máquina de ensaio universal (Instron). Os dados foram submetidos ao teste ANOVA 3 fatores e Tukey (α=0,05). Para ambos os arcos, independentemente do tipo de dente e tipo de braquete, os valores médios de tensão mais elevados foram mostrados pelo ângulo de 20°, seguido pelos ângulos de 15°, 10°, e 5°, que diferiram estatisticamente entre si. Em geral, para ângulos de 5°, 10° e 15°, os braquetes convencionais e versáteis apresentaram valores de força significativamente mais elevados em todos os dentes, braquetes tip-edge e controle apresentaram os mais baixos. Os maiores valores de força foram observados nos incisivos centrais e laterais com braquetes convencionais e versáteis e no primeiro e segundo pré-molares com braquetes auto-ligantes passivo e controle. Os braquetes convencionais apresentaram as forças mais elevadas, os braquetes controle e tip-edge apresentaram os valores mais baixos. Os dentes que sofreram as maiores forças foram os incisivos laterais, e os que sofreram menos foram os segundos pré-molares.

5.
Braz. dent. j ; 32(4): 55-61, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345512

ABSTRACT

Abstract The purpose of this in vitro study was to evaluate the force decrease of different elastomeric chains after different times: initial, 10 minutes, 1 day, 28 days and after mechanical brushing. Twenty orthodontic elastomeric chains segments were utilized for each commercial brand. Initially, the elastomeric chain of 15mm long were immediate stretched up to 20 mm in an Instron and the force was measured in gf. After all specimens were placed stretched on rectangular acrylic jigs with distance of 20 mm, immersed in deionized water at 37oC for 10 minutes and the force (gf) was measured again. Five test measurements of remaining force were made at the following time intervals: initial, 10 minutes, 1 day, 28 days and mechanical brushing. After 28 days, the acrylic plates with the specimens were adapted in the mechanical brushing machines (MSCT 3) and the elastomeric chains were submitted to mechanical brushing and the force (gf) measure again. The force (gf) was submitted to mixed-model ANOVA and Sidak post-hoc test (α=0.05). A statistically significant reduction in the force was found for all orthodontic elastomeric chain types after 1 day, 28 days and mechanical brushing (p<0.05). Morelli and 3M Unitek elastomeric chains showed significantly higher force than Abzil and GAC (p<0.05) after 1 day, 28 days and mechanical brushing. In conclusion, the force delivered by all elastomeric chains decayed rapidly over time. Morelli and 3M Unitek elastomeric chains consistently had a significantly greater force after mechanic brushing, while GAC the lowest.


Resumo O objetivo deste estudo in vitro foi avaliar a redução da força de diferentes cadeias elastoméricas após diferentes tempos: inicial, 10 minutos, 1 dia, 28 dias e após escovação mecânica. Vinte segmentos de cadeias elastoméricas ortodônticas foram utilizadas para cada marca comercial. Inicialmente, a cadeia elastomérica de 15 mm de comprimento foi esticada imediatamente até 20 mm na Instron e a força foi medida em (gf). Após, todas as amostras foram adaptadas esticadas em placas retangulares de acrílico na distância de 20 mm, imersas em água deionizada a 37o C por 10 minutos e a força (gf) foi medida novamente. Cinco medidas de força foram feitas nos seguintes intervalos de tempo: inicial, 10 minutos, 1 dia, 28 dias e após a escovação mecânica. Após 28 dias, as placas de acrílico com as amostras foram adaptadas na máquina de escovação (MSCT 3) e as cadeias elastoméricas foram submetidas a escovação mecânica e a medida de força (gf) novamente. Os dados da força (gf) foram submetidos a ANOVA modelo misto e teste post-hoc de Sidak (α = 0,05). Uma redução estatisticamente significativa na força foi encontrada para todos os tipos de cadeia elastomérica ortodôntica após 1 dia, 28 dias e escovação mecânica (p<0,05). As cadeias elastoméricas Morelli e 3M Unitek apresentaram força significativamente superior em relação a Abzil e GAC (p<0,05) após 1 dia, 28 dias e escovação mecânica. Em conclusão, a força distribuída por todas as cadeias elastoméricas decaiu rapidamente com o tempo. As cadeias elastoméricas Morelli e 3M Unitek consistentemente tiveram uma força significativamente maior após a escovação mecânica, enquanto GAC a mais baixa.


Subject(s)
Orthodontic Appliances , Elastomers , Stress, Mechanical , Toothbrushing , Materials Testing , Elasticity
6.
Braz. dent. j ; 32(4): 106-115, July-Aug. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1345518

ABSTRACT

Abstract The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate (CHX) on microtensile bond strength (µTBS) between an adhesive system and under 3 dentin conditions. For that, this study evaluated the adhesive interface at initial, after 6 months and 1 year of storage. Forty-eight human third molars were prepared and randomly divided into 3 groups, according to dentin substrates: sound dentin (Sd), caries-infected dentin (Ci) and caries-affected dentin (Ca). The groups were subdivided into two according to the dentin pre-treatment: application of 2% CHX or without pre-treatment (control). The dentin surfaces were etched with 35% phosphoric acid gel and bonded with Adper Single Bond 2 (3M ESPE) adhesive system according to manufacturer's instructions. Subsequently, the specimens were stored in deionized water at 37°C for 24h, 6 months and 1 year. Two additional teeth were used to analyze the bonding interfaces by SEM. Data was submitted to three-way ANOVA in a split plot design and Tukey's test (α = 0.05). The results showed that Ci decreased µTBS values when compared to Ca and Sd, regardless storages time or treatment. Stored samples for 6 months and 1 year decreased the µTBS for the control group, but no difference was found between storages time for the CHX group. As a conclusion, the 2% CHX application after etching showed improved dentin bond strength in the storage time, regardless of the substrates evaluated.


Resumo O objetivo deste estudo foi avaliar o efeito do digluconato de clorexidina 2% (CHX) na resistência de união à microtração (µTBS) entre um sistema adesivo e sob 3 condições de dentina. Para tanto, este estudo avaliou a interface adesiva no início, após 6 meses e 1 ano de armazenamento. Quarenta e oito terceiros molares humanos foram preparados e divididos aleatoriamente em 3 grupos, de acordo com os substratos dentinários: dentina hígida (Dh), dentina infectada por cárie (Di) e dentina afetada por cárie (Da). Os grupos foram subdivididos em dois de acordo com o pré-tratamento: aplicação de CHX 2% ou sem pré-tratamento (controle). As superfícies da dentina foram condicionadas com gel de ácido fosfórico a 35%, em seguida, utilizou-se o sistema adesivo Adper Single Bond 2 (3M ESPE) de acordo com as instruções do fabricante. Posteriormente, os corpos-de-prova foram armazenados em água deionizada a 37°C por 24h, 6 meses e 1 ano. Dois dentes adicionais foram usados ​​para analisar as interfaces de união no MEV. Os dados foram submetidos a ANOVA três fatores em esquema de parcela subdividida e ao teste de Tukey (α = 0,05). Os resultados mostram que a Di diminuiu os valores de µTBS quando comparado as Da e Dh, independente do tempo de armazenamento ou tratamento. Amostras armazenadas por 6 meses e 1 ano diminuíram a µTBS para o grupo de controle, mas nenhuma diferença foi encontrada entre o tempo de armazenamento para o grupo CHX. A aplicação de CHX 2% após o condicionamento apresentou melhora na resistência de união à dentina no tempo de armazenamento, independente dos substratos avaliados.


Subject(s)
Humans , Dental Bonding , Dentin-Bonding Agents , Tensile Strength , Materials Testing , Composite Resins , Resin Cements , Dentin
7.
Rev. odontol. UNESP (Online) ; 49: e20200021, 2020. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1139429

ABSTRACT

Introduction: The sterilization and disinfection procedures should be adapted to the chemical profile of the metal alloys present in the instruments. Objective: This study aimed to perform a micrographic assessment on the surface characteristics of the widia of orthodontic pliers with two alloy compositions subjected to the action of 0.2% peracetic acid and intensive use. Material and method: Twenty distal cutting pliers were divided into two groups (n=10) according to widia composition (%wt): W1- 85% to 87% of tungsten carbide (TC) and other components in the proportion of 13% to 15% and W2 - 87.5% to 88.5% of tungsten carbide and 11.5% to 12.5% for other components. All the pliers were assessed in a stereoscopic magnifying glass (32x) after three treatments: before use (T0); after cutting 100 segments of rectangular stainless-steel wires - intensive use (T1); and after 100 sterilization cycles in 0.2% peracetic acid and intensive use (T2). The cutting sites of all pliers were standardized. Widia regions were defined by line "A" representing T1 and line "B" representing T2. A frequency distribution table and Fisher's exact test (α=0.05) was performed. We assessed two widia from each composition and treatment in SEM and energy-dispersive X-ray spectroscopy (EDS/SEM). Result: The results showed that W1 pliers presented significantly fewer defects after the sterilization cycles with peracetic acid and intensive use than W2 pliers (p=0.0198). There were no differences between both pliers after intensive use (p=1.000). Conclusion: The SEM images and EDS analyses showed changes in widia surfaces after the different treatments. Widia composition affected the resistance of the orthodontic pliers after sterilization cycles with 0.2% peracetic acid and intensive use.


Introdução: Os procedimentos de esterilização e desinfecção devem ser adaptados ao perfil químico das ligas metálicas presentes nos instrumentos. Objetivo: O objetivo do estudo foi realizar uma avaliação micrográfica das características da superfície da widia de alicates ortodônticos com duas composições de ligas submetidas à ação de ácido peracético a 0,2% e uso intensivo. Material e método: Vinte alicates de corte distal foram divididos em dois grupos (n=10), de acordo com a composição widia (% em peso): W1- 85% a 87% de carboneto de tungstênio e outros componentes na proporção de 13% a 15% e W2 - 87,5% a 88,5% de carboneto de tungstênio e 11,5% a 12,5% para outros componentes. Os alicates foram avaliados em uma lupa estereoscópica (32x) após três tratamentos: antes do uso (T0); após corte de 100 segmentos de fios retangulares de aço inoxidável- uso intensivo (T1); após 100 ciclos de esterilização em ácido peracético a 0,2% e uso intensivo (T2). Os locais de corte dos alicates foram definidos pela linha "A" representando T1 e pela linha "B" representando T2. Foi realizada uma tabela de distribuição de frequências e o teste exato de Fisher (α=0,05). As widias foram avaliadas em MEV e Espectroscopia de Energia Dispersiva. Resultado: Os alicates W1 apresentaram defeitos significativamente menores após os ciclos de esterilização com ácido peracético e uso intensivo do que os alicates W2 (p=0,0198). Não houve diferenças entre os dois alicates após uso intensivo (p=1.000). Conclusão: As imagens de MEV/EDS mostraram alterações nas superfícies widia após os diferentes tratamentos. A composição widia afetou a resistência do alicate ortodôntico após ciclos de esterilização com ácido peracético a 0,2% e uso intensivo.


Subject(s)
Orthodontics , Spectrum Analysis , Microscopy, Electron, Scanning , Sterilization , Disinfection , Dental Disinfectants , Dental Instruments
8.
Rev. odontol. UNESP (Online) ; 48: e20190022, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1020754

ABSTRACT

Abstract Introduction The orthodontic movement is directly influenced by the ability of orthodontic wires to slide through brackets and tubes. Therefore, the main concern during orthodontic movement corresponds to the frictional forces generated at the bracket-orthodontic wire interface. Objective This study aimed to evaluate the frictional resistance of esthetic orthodontic wires. Material and method Fifty test brackets were obtained and divided into five groups (n = 10) based on the type of rectangular orthodontic wire, as follows: conventional metallic wire (Morelli, Brazil) (G1, control group) and esthetic wires (G2, Ortho Organizer; G3, Tecnident; G4, Trianeiro; and G5, TP Orthodontics). The following materials and conditions were used: 0.019 x 0.025-inch wires, ceramic brackets with edgewise prescription, torque and/or angulation of 0°, and 0.022 x 0.028-inch slots. The specimens were tested for their tensile strength using an Instron universal test machine at a speed of 1.0 mm / min and a load cell of 500N. The tensile strength data were analyzed by one-way analysis of variance (ANOVA) followed by Tukey's post-hoc test, with a 5% significance level. Result The frictional resistance (N) of the metallic orthodontic wire (8.07 ± 0.43) was significantly higher than that of the esthetic wires: Ortho Organizer (4.01 ± 0.25), Tecnident (3.87 ± 0.31), Trianeiro (4.47 ± 0.26) and TP Orthodontics (4.49 ± 0.30) (p <0.05), with no significant difference between them (p> 0.05). Conclusion To conclude, the esthetic orthodontic wires tested herein showed less frictional resistance as compared to the conventional metallic wire.


Resumo Introdução O movimento ortodôntico bem sucedido está diretamente relacionado com a capacidade de os fios ortodônticos deslizarem sobre os bráquetes e tubos ortodônticos. Portanto, durante a movimentação ortodôntica a principal preocupação está diretamente ligada a fricção entre o suporte e o fio. Objetivo O objetivo deste estudo foi avaliar a influência de fios ortodônticos estéticos na resistência ao atrito. Material e método Foram utilizados 50 bráquetes-teste divididos em 5 grupos, de acordo com o fio retangular (n=10): G1 - grupo controle: fio metálico convencional (Morelli, Brasil) e fios estéticos (G2 - Ortho Organizer; G3 - Tecnident; G4 - Trianeiro; e, G5 - TP Orthodontics). Todos os fios apresentavam 0,019 x 0,025 polegadas e o bráquete era cerâmico, prescrição Edgewis e, torque e/ou angulação 0° e, canaleta 0,022 x 0,028 polegadas. O teste de resistência ao atrito sob força de tração foi realizado em uma máquina de ensaio universal Instron à velocidade de 1,0 mm/min e célula de carga de 500N. Os dados de resistência ao atrito foram submetidos à análise de variância (ANOVA) um fator e ao Teste de Tukey com nível de significância de 5%. Resultado O atrito (N) do fio metálico (8,07±0,43) foi significativamente maior que os fios ortodônticos estéticos: Ortho Organizer (4,01±0,25), Tecnident (3,871±0,31), Trident (4,47±0,26) e, TP (4,49±0,30) (p<0,05). Nenhuma diferença estatisticamente significativa foi observada entre os fios estéticos (p>0,05). Conclusão Conclui-se que os fios ortodônticos estéticos apresentam menor resistência ao atrito quando comparado ao fio metálico.


Subject(s)
Orthodontic Wires , Tensile Strength , Friction , Orthodontics , Orthodontic Brackets , Dental Porcelain
9.
Braz. j. oral sci ; 18: e191647, jan.-dez. 2019. ilus
Article in English | LILACS, BBO | ID: biblio-1095367

ABSTRACT

Aim: The present study aimed to assess, in vitro, the effect of chlorhexidine on the potentiation of polycrystalline ceramic bracket staining. Methods: Seventy-two polycrystalline ceramic brackets of upper right central incisors were divided into six groups (n=12) according to immersion solution. The groups were G1 - distilled water (control); G2 - chlorhexidine; G3 - coffee; G4 - red wine; G5 - chlorhexidine associated with coffee; and G6 - chlorhexidine associated with red wine. The samples were analyzed by means of a spectrophotometer according to the CIEL*a*b* system, and color change (ΔE*) was calculated. The readings were performed at the following times: T0 - After package removal and T1 - After staining. The data were analyzed by Kruskal Wallis and t tests (p<0.05) at 5% significance level. Results: The total color variation (ΔE*) was greater in the group that received chlorhexidine associated with red wine (p<0.05) and lower in the groups that received distilled water. All other groups showed greater value variations when compared to G1 and G2. Group G6 showed a greater color change due to the potentiation of chlorhexidine with the dye substance. Conclusion: It is concluded that chlorhexidine potentiates the staining caused by red wine in polycrystalline ceramic brackets


Subject(s)
Ceramics , Chlorhexidine , Orthodontic Brackets , Mouthwashes
10.
Rev. odontol. UNESP (Online) ; 48: e20190048, 2019. tab, ilus
Article in English | LILACS, BBO | ID: biblio-1043169

ABSTRACT

Abstract Introduction In recent years, there has been an increasing demand for esthetic treatments, especially among orthodontic patients. Objective This study determined the fracture strength of monocrystalline and polycrystalline ceramic brackets of different manufacturers during archwire torque. Material and method Sixty ceramic brackets (Roth, right upper central incisors, 0.022 x 0.028-inch slot) were allocated into two groups (30 specimens per group) according to the type of ceramics: monocrystalline and polycrystalline. Subsequently, the groups were divided into three subgroups (n = 10) according to the manufacturer: Orthometric, Eurodonto and Ortho Technology. Sixty PVC cylinders were filled with chemically activated acrylic resin (CAAR), the brackets were fixed with CAAR onto the cylinder surface and the excess material was used to partially cover the base of the bracket. After 24h, the U-shaped wire base (0.019 x 0.025 inches; 6 mm height and width) was inserted into the bracket slot and fixed thereon with a stainless-steel wire. Vertical folds were made at the ends of the "U" to support the universal test machine chisel. The fracture strength test was performed at a speed of 1.0 mm/min until fracture into a universal test machine (Instron). The data were recorded, transformed into g.mm and submitted to two-way ANOVA followed by Tukey's post-hoc test (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Result Monocrystalline brackets showed a higher fracture strength than polycrystalline brackets, regardless of the manufacturer (p<0.05). The highest fracture strength values were observed in Ortho Technology and Orthometric brackets, with no significant difference between them (p>0.05). Conclusion Monocrystalline ceramic brackets have a higher fracture strength than polycrystalline brackets, with significant manufacturer-dependent differences.


Resumo Introdução A demanda por tratamentos estéticos tem crescido nos últimos anos, sendo cada vez mais forte a preocupação com a estética por parte dos pacientes que buscam o tratamento ortodôntico. Objetivo Este estudo avaliou a resistência à fratura de bráquetes cerâmicos monocristalinos e policristalinos de diferentes fabricantes quando submetidos ao torque do fio. Material e método Sessenta bráquetes cerâmicos (Roth, incisivos centrais superiores direito, canaleta 0,022 x 0,028 polegadas) foram divididos em 2 grupos (30 espécimes por grupo) de acordo com o tipo da cerâmica: monocristalina e policristalina. Posteriomente estes grupos foram divididos em 3 sub-grupos (n=10) de acordo com o fabricante: Orthometric, Eurodonto e Ortho Technology. Segmentos de fio de aço inoxidável retangular (0,019 x 0,025 polegadas) foram dobrados em forma de "U", sendo que a base do "U" foi inserida na canaleta do bráquete e fixado com fio de amarilho em aço inoxidável (0,008mm). Nas extremidades do "U" foram realizadas dobras verticais para servir de apoio para o cinzel da máquina de ensaio universal Instron. O ensaio de resistência à fratura foi realizado à velocidade de 1,0 mm/min até ocorrer a fratura. Os dados foram registrados, transformados em g.mm e submetidos à ANOVA dois fatores e ao teste de Tukey (SAS Institute Inc., Cary, NC, USA, version 9.3) (α=5%). Resultado Os bráquetes monocristalinos apresentaram maior resistência à fratura em relação aos policristalinos, independente do fabricante (p<0,05). Os maiores valores de resistência à fratura foram obtidos com os bráquetes da Ortho Technology e Orthometric, os quais não diferiram estatisticamente entre si (p>0,05). Conclusão Bráquetes monocristalinos possuem maior resistência à fratura em relação aos policristalinos com diferenças na resistência à fratura entre os diferentes fabricantes.


Subject(s)
Orthodontic Brackets , Torque , Esthetics, Dental , In Vitro Techniques
11.
Braz. dent. j ; 29(3): 268-274, May-June 2018. tab, graf
Article in English | LILACS | ID: biblio-951545

ABSTRACT

Abstract The aim was to evaluate the influence of different dentin preparation mode in the smear layer characteristics (SL), hybrid layer (HL), and microtensile bond strength (µTBS) to dentin with two resin cements. The occlusal dentin of 120 third molars was exposed. The teeth were divided into 4 groups (n=30) according to the dentin preparation mode: 1- fine grain diamond bur; 2- coarse grain diamond bur; 3- multi laminate carbide steel bur; and, 4- ultrasonic CV Dentus diamond bur. Each treated dentin group was divided into 2 sub-groups (n=15) according to the resin cement: (1) RelyX U200 and (2) RelyX ARC. Resin composite blocks were cemented on dentin. After storage at 37o C for 24 h, beams with a cross section area of 1.0 mm2 were obtained, and tested in a universal testing machine at a crosshead speed of 0.5 mm/min. Two additional teeth for each sub-group were prepared to analyze the SL and HL on a scanning electron microscopy. According to Kruskal-Wallis test and Dunn tests, there was no significant difference in µTBS among the rotary instruments within each resin cement group. RelyX ARC obtained higher µTBS values compared to RelyX U200 (p<0.05). RelyX ARC formed evident HL, which was not observed for RelyX U200. The dentin mode preparation did not influence the µTBS of the resin cements. The SL was different for all instruments. The cementing agent is more determinant in the hybrid layer formation and bond strength to dentin than the instruments applied on dentin.


Resumo O objetivo deste estudo foi avaliar a influência de diferentes modos de preparação da dentina nas características da smear layer (SL), da camada híbrida (CH) e na resistência de união à microtração (RUµT) à dentina com dois cimentos resinosos. A dentina oclusal de 120 terceiros molares humanos foi exposta. Os dentes foram divididos em 4 grupos (n=30) de acordo com o modo de preparação da dentina: 1 - ponta diamantada de granulação fina; 2 - ponta diamantada de granulação grossa; 3 - ponta de carboneto de aço multilaminada; 4 - ponta diamantada ultrassônica. Cada grupo foi subdividido em dois subgrupos (n=15) de acordo com o cimento resinoso: (1) RelyX U200 e (2) RelyX ARC. Blocos de resina composta foram cimentados na dentina. Após armazenamento a 37 °C por 24 h, as amostras foram cortadas para obter palitos com área de 1,0 mm2, os quais foram testados em máquina de ensaio universal com velocidade de 0,5 mm/min. Dois dentes adicionais por subgrupo foram preparados para analisar as características da SL e da CH em microscópio eletrônico de varredura. De acordo com o teste de Kruskal-Wallis e o teste de Dunn, não houve diferença significativa na RUµT entre os instrumentos rotatórios para cada cimento resinoso. RelyX ARC obteve maiores valores de RUµT em comparação ao RelyX U200 (p<0,05). RelyX ARC formou uma CH evidente, o que não foi observado para o RelyX U200. O modo de preparação da dentina não influenciou na RUµT dos cimentos resinosos. A SL foi diferente para todos os instrumentos. O agente de cimentação foi mais determinante na formação da camada híbrida e na resistência de união do que os instrumentos utilizados para preparar a dentina.


Subject(s)
Humans , Tensile Strength , Dental Bonding , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Dental Cavity Preparation/methods , Dentin/chemistry , Polyethylene Glycols , Polymethacrylic Acids , Microscopy, Electron, Scanning , Smear Layer , Bisphenol A-Glycidyl Methacrylate , Dental Stress Analysis , Molar, Third/chemistry
12.
Braz. dent. j ; 29(1): 82-87, Jan.-Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-888716

ABSTRACT

Abstract The goal of this study was to evaluate in vitro the effect of the photoinitiator phenylpropanedione (PPD), alone or combined with camphorquinone (CQ), on color stability of photoactivated resin cements and their bond strength to ceramics using a micro-shear test. Four resin cements were used: a commercial brand cement (RelyX Veneer®) and 3 experimental cements with different types and concentration of photoinitiators. For color analysis, ceramic discs were cemented on bovine dentin specimens to simulate indirect restorations (n=8) and were exposed to UV for 120 h and tested for color alteration using a reflectance spectrophotometer and the CIEL*a*b* system. Data were analyzed by Anova and Tukey's test at 5% significance level. The color test results did not present statistically significant difference for the ∆E for all the studied cements, neither for ∆L, ∆a and ∆b. For the bond strength, all the studied cements showed statistically significant differences to each other, with the highest result for the RelyX Veneer® (29.07 MPa) cement, followed by the cement with CQ (21.74 MPa) and CQ+PPD (19.09 MPa) cement; the lowest result was obtained by the cement using only PPD as a photoinitiator (13.99 MPa). So, based on the studied parameters, PPD was not advantageous as photoinitiator of resin cements, because it showed a low value of bond strength to the ceramics and no superior color stability.


Resumo O objetivo deste estudo foi avaliar in vitro o efeito do fotoiniciador fenilpropanodiona (PPD), isoladamente ou em associação com a CQ, sobre a estabilidade de cor de cimentos resinosos fotoativados e sua resistência de união adesiva à cerâmica, por teste de microcisalhamento. Foram utilizados 4 cimentos resinosos, sendo um comercial (RelyX Veneer®) e 3 experimentais, diferindo entre si quanto ao tipo e concentração dos fotoiniciadores. Para a análise de cor foram cimentados discos cerâmicos sobre dentina bovina, simulando restaurações indiretas (n=8), sendo expostos a 120 h de UV e testados quanto às alterações de cor, que foram mensuradas empregando a escala CIEL*a*b*, por meio de espectrofotômetro de reflectância. Os dados obtidos foram verificados quanto à distribuição normal, submetidos a Anova e ao teste complementar Tukey, todos com significância de 5%. Os resultados do teste de cor não apresentam diferença estatisticamente significante para o ∆E dos 4 cimentos estudados, tampouco para ∆L, ∆a e ∆b. Para a resistência de união, todos os cimentos estudados apresentaram diferenças estatisticamente significantes entre si, com o maior resultado para o cimento comercial RelyX Veneer® (29,07 MPa), seguido pelo cimento com CQ (21,74 MPa), e cimento de CQ+PPD (19,09 MPa); o menor resultado foi obtido com o cimento utilizando apenas o PPD como fotoiniciador (13,99 MPa). Portanto, para os parâmetros estudados, o PDD não se mostrou vantajoso como fotoiniciador de cimentos resinosos, pois apresentou baixo valor de resistência de união à cerâmica e não demonstrou superioridade quanto à estabilidade de cor.


Subject(s)
Animals , Cattle , Dental Bonding/methods , Light , Resin Cements/chemistry , Color , Materials Testing , Spectrophotometry/methods
13.
Braz. dent. j ; 29(1): 76-81, Jan.-Feb. 2018. tab, graf
Article in English | LILACS | ID: biblio-888717

ABSTRACT

Abstract The aim of this study was to evaluate Knoop hardness of different shades of a resin cement light-cured directly or through ceramic discs, measured 15 min or 24 h after light exposure, and at different depths. Specimens of a commercial resin cement (Variolink Veneer) in seven shades, were fabricated in an elastomeric mold, covered with a mylar strip, a 0.7 mm thick ceramic disc (IPS e.max Press) was placed and the cement was light-activated for 20 s using a blue LED (Radii-Cal). The cured resin cement specimens were transversely wet-flattened to their middle portion and microhardness (Knoop) values were recorded at 15 min after light exposure and after deionized water storage at 37 ºC for 24 h. Five indentations were made in the cross-sectional area at 100 and 700 μm depths from the top surface. Ten specimens were made for each test conditions. Data were submitted to ANOVA split-plot design (shade, post-cure time, mode of activation and depth), followed by Tukey post hoc test (α=0.05). Significant differences for shade (p<0.0001), mode of activation (p<0.001), post-cure time (p<0.0001) and depth (p<0.0001) were detected. No significant interactions (p>0.05) were found, except for shade x post-cure time (p<0.0045) and mode of activation x post-cure time (p<0.0003). Resin cement shade has a significant effect on Knoop hardness. Indirect activation through a ceramic material reduced significantly Knoop hardness. Hardness Knoop significantly increased after 24 h in all cements shades compared to values obtained after 15 min. Resin cement depth significantly reduced Knoop hardness.


Resumo O objetivo deste estudo foi avaliar a dureza Knoop de diferentes cores de um cimento resinoso fotoativado diretamente ou através da interposição de um disco de cerâmica, medindo 15 min ou 24 h após exposição à luz, em diferentes profundidades. Amostras do cimento resinoso (Variolink Veneer) em sete cores foram fabricados num molde de elastômero, coberto com tira de poliéster, seguido de um disco cerâmico (IPS e.max Press) com 0.7 mm de espessura e fotoativado por 20 s com o aparelho LED (IPS e.max Press). O cimento resinoso fotoativado foi transversalmente desgastado na porção média e os valores de microdureza Knoop foram obtidos após 15 min após exposição à luz e após armazenagem em água deionizada à 37 °C por 24 h. Cinco penetrações foram feitas na secção transversal à 100 e 700 μm da superfície de topo. Dez amostras foram confeccionadas para cada condição de teste. Os dados foram submetidos à Análise de Variância em esquema de parcelas subdivididas (cor, tempo pós-ativação, modo de ativação e profundidade), seguido pelo teste de Tukey post hoc (α=0,05). Diferença significante para a cor (p<0,0001), modo de ativação (p<0,001), tempo pós-ativação (p<0,0001) e profundidade (p<0,0001) foi detectada. Nenhuma interação significante foi encontrada (p>0,05), exceto para a interação cor x tempo pós-ativação (p<0,0045) e modo de ativação x tempo pós-ativação (p<0,0003). A cor do cimento resinoso teve significante efeito na dureza Knoop. A ativação indireta através do material cerâmico reduziu significativamente a dureza Knoop. A dureza Knoop aumentou significativamente após 24 h em todas as cores do cimento comparados aos valores obtidos após 15 min. A profundidade do cimento resinoso reduziu significativamente os valores de dureza Knoop.


Subject(s)
Ceramics , Color , Hardness , Resin Cements , Curing Lights, Dental , Polymerization
14.
Braz. j. oral sci ; 16: e17033, jan.-dez. 2017. ilus
Article in English | LILACS, BBO | ID: biblio-883922

ABSTRACT

Aim: To evaluate, in vitro, the effect of adhesive and bonding materials on the shear bond strength (SBS) of metallic brackets bonded to bovine teeth. Methods: Bovine teeth were embedded with acrylic resin, etched with 35% phosphoric acid for 20 s, rinsed, dried for 20 s and divided into 8 groups (n=20), according to the bonding materials and adhesive: Groups 1 and 5 ­ Transbond XT; Groups 2 and 6 ­ Fill Magic; Groups 3 and 7 ­ Biofix; and, Groups 4 and 8 ­ Orthocem. One layer of adhesive 3 M Unitek (Group 1), and one layer of Single Bond Universal Adhesive (Groups 2, 3 and 4) were applied and light-cured with LED for 10 s. Brackets were bonded to the buccal surface with four bonding materials and light-cured with LED for 40 s. SBS was carried out after 24 h and thermocycling (7,000 cycles - 5°/55 °C). Data were submitted to two way ANOVA and Tukey's post hoc test (α=0.05). The Adhesive Remaining Index (ARI) was evaluated at 8×. Results: The adhesive was effective in increasing the SBS for all bonding materials (p<0.05). Significant difference (p<0.05) on the SBS was observed between bonding materials with or without adhesive. The ARI showed a predominance of scores 0 for all groups. Conclusions: The adhesive improved significantly the SBS of the brackets to teeth. Different SBS values occurred among the bonding materials. ARI index showed predominance of score 0 for all groups (AU)


Subject(s)
Cattle , Adhesives , Orthodontic Brackets , Shear Strength
15.
Rev. odontol. UNESP (Online) ; 46(3): 179-183, May-June 2017. tab, ilus
Article in English | LILACS, BBO | ID: biblio-902650

ABSTRACT

Objective: To evaluate in vitro the effect of different treatments of the ceramic surface and thermal cycling on the shear bond strength (SBS) of metallic brackets bonded to feldspathic ceramic. Material and method: Ceramic cylinders were divided into four groups (n=4) according to the treatment of ceramic surface: G1-Clearfil Ceramic Primer silane and Transbond XT (CCPT); G2-etched with 10% hydrofluoric acid (HFA) for 60 s, CCP and Transbond XT (ACCPT); G3-etched with 10% HFA for 60 s, Ambar Adhesive and Transbond XT (AAAT); and, G4 - etched with 10% HFA for 60 s, RelyX Ceramic Primer silane -RCP, adhesive primer Transbond and Transbond XT (ACPPT). Brackets were bonded to the cylinders with Transbond XT and light-activated for 40 s with LED Radii Plus. All specimens were stored in deionized water at 37 °C for 24 h, and two cylinders from each group were subject to 7,000 thermal cycles in a thermal cycler (5 °C/55 °C). After storage and thermal cycling, the SBS test was performed at a crosshead speed of 1 mm/min. Data were subjected to two-way ANOVA and Tukey's post hoc test (α=0.05). Result: The SBS of ACCPT was significantly higher than the other groups (p<0.05). The specimens submitted to thermal cycling showed significantly lower SBS than those without thermal cycling (p<0.05), regardless the ceramic surface treatment. The ARI showed predominance of score 0 for all groups. Conclusion: Acid etching, CCP silane and Transbond XT method obtained the best results for bracket bonding. Thermal cycling reduced SBS for all groups. Score 0 was predominant for ARI in all groups.


Objetivo: Avaliar in vitro o efeito de diferentes tratamentos de superfície da cerâmica e ciclagem térmica na resistência da união ao cisalhamento (RUC) de bráquetes metálicos colados na cerâmica felspática. Material e método: Cilindros cerâmicos foram separados em 4 grupos (n=4) de acordo com os tratamentos da superfície da cerâmica: G1-Clearfil Ceramic Primer silano e Transbond XT (CCPT); G-condicionamento com ácido hidrofluorídrico a 10% (AHF) por 60s, CCP e Transbond XT (ACCPT); G3-condicionamento com AHF a 10% por 60s, Adesivo Ambar e Transbond XT (AAAT); e, G4 condicionamento com AHF a 10% por 60s, RelyX Ceramic Primer silano, primer adesivo Transbond e Transbond XT (ACPAT). Os bráquetes foram fixados nos cilindros com Transbond XT e fotoativado por 40s com LED Radii Plus. Todas as amostras foram armazenadas em água deionizada a 37 °C por 24 h e dois cilindros de cada grupo foram submetidos a 7.000 ciclos térmicos na máquina para ciclagem térmica (5 °C/55 °C). Após armazenagem e ciclagem térmica, a RUC foi realizada à velocidade de 1 mm/min. Na Análise de Variância de 2 fatores e ao teste de Tukey's post hoc test (α=0,05) a RUC do G2 foi significante maior do que dos demais grupos (p<0,05). Resultado: As amostras submetidas à ciclagem térmica apresentaram valores de RUC significantemente menores do que as amostras sem ciclagem térmica (p<0,05), independente do tratamento de superfície da cerâmica. Conclusão: Nas condições desse estudo o melhor resultado para colagem foi obtido com o condicionamento, silano CCP e Transbond XT. A ciclagem térmica reduziu a RUC em todos os grupos.


Subject(s)
Silanes , Ceramics , Analysis of Variance , Orthodontic Brackets , Dental Cements , Shear Strength , In Vitro Techniques , Dental Bonding
16.
Braz. dent. j ; 28(2): 206-209, mar.-Apr. 2017. graf
Article in English | LILACS | ID: biblio-839129

ABSTRACT

Abstract The aim of this study was to evaluate the effect of different number of thermal cycles on the shear bond strength (SBS) of metallic orthodontic brackets bonded to feldspathic ceramic by a composite resin. Twenty-five ceramic cylinders were etched with 10% hydrofluoric acid for 60 s and received two layers of silane. Brackets were bonded to the cylinders using Transbond XT and assigned to 5 groups (n=5): Group 1 - Control group (without thermal cycling); Group 2 - 500 thermal cycles; Group 3 - 5,000 thermal cycles; Group 4 - 7,000 thermal cycles and Group 5 - 10,000 thermal cycles. Light-activation was carried out by Radii Plus LED. SBS testing was carried out after 24 h of storage in deionized water and thermal cycling (5/55 oC and 30 s dwell time). Five brackets were bonded to each cylinder, totalizing 25 brackets for each group. Data were submitted to one-way ANOVA and Tukey’s test (α=0.05). The Adhesive Remnant Index (ARI) was evaluated at 8× magnification. The SBS (MPa) of control group (9.3±0.8), 500 (9.0±0.7) and 5,000 (8.4±0.9) thermal cycles were significantly higher than those after 7,000 (6.8±0.6) and 10,000 (4.9±1.0) thermal cycles (p<0.05). The ARI showed a predominance of Scores 0 (adhesive failure) prevailed in all groups, as shown by the ARI, with increased scores 1 and 2 (mixed failures) for control group and 500 thermal cycles. In conclusion, thermal fatigue may compromise the bonding integration between metallic brackets and ceramic restorations. For in vitro testing, use of at least 7,000 cycles is advised to result in significant fatigue on the bonding interface.


Resumo O objetivo neste estudo foi avaliar o efeito de diferentes números de ciclos térmicos na resistência da união de braquetes metálicos à cerâmica feldspática usando resina composta. Vinte e cinco cilindros de cerâmica foram condicionados com ácido fluorídrico a 10% por 60 s e duas camadas de silano. Braquetes foram fixados nos cilindros usando Transbond XT e depois separados em 5 grupos (n=5): Grupo 1 - Grupo Controle (sem ciclagem térmica); Grupo 2 - 500 ciclos térmicos; Grupo 3 - 5.000 ciclos térmicos; Grupo 4 - 7.000 ciclos térmicos e Grupo 5 - 10.000 ciclos térmicos. A fotoativação foi realizada com aparelho LED Radii Plus. O ensaio de resistência de união ao cisalhamento foi realizado após armazenagem por 24 h em água deionizada ou após a ciclagem térmica (5º/55 ºC, com banhos de 30 s cada). Cinco braquetes foram fixados em cada cilindro, totalizando 25 bráquetes por grupo. Os dados foram submetidos à análise de variância de um fator e ao teste de Tukey (α=0,05). O Índice de Remanescente Adesivo (IRA) foi avaliado com aumento de 8x. Os valores de resistência (MPa) dos grupos controle (9,3±0,8), 500 (9,0±0,7) e 5.000 (8,4±0,9) ciclos térmicos foram significantemente maiores do que os grupos submetidos à 7.000 (6,8±0,6) e 10.000 (4,9±1,0) ciclos térmicos (p<0,05). O IRA mostrou predominância do escore 0 para todos os grupos, com aumento de escores 1 e 2 para os grupos controle e submetidos a 500 ciclos térmicos. Em conclusão, a fadiga térmica pode comprometer a união entre os braquetes metálicos e as restaurações cerâmicas. Para testes in vitro, o uso de pelo menos 7.000 ciclos é recomendado para determinar fadiga significante na interface de união.


Subject(s)
Ceramics , Dental Bonding , Materials Testing , Orthodontic Brackets
17.
Braz. dent. j ; 28(1): 16-23, Jan.-Feb. 2017. tab, graf
Article in English | LILACS | ID: biblio-839124

ABSTRACT

Abstract The aim of this study was to evaluate the μTBS in different dentin substrates and water-storage periods. Twenty-four dentin blocks obtained from sound third molars were randomly divided into 3 groups: Sound dentin (Sd), Caries-affected dentin (Ca) and Caries-infected dentin (Ci). Dentin blocks from Ca and Ci groups were subjected to artificial caries development (S. mutans biofilm). The softest carious tissue was removed using spherical drills under visual inspection with Caries Detector solution (Ca group). It was considered as Ci (softer and deeply red stained dentin) and Ca (harder and slightly red stained dentin). The Adper Single Bond 2 adhesive system was applied and Z350 composite blocks were built in all groups. Teeth were stored in deionized water for 24 h at 37 ºC and sectioned into beams (1.0 mm2 section area). The beams from each tooth were randomly divided into three storages periods: 24 h, 6 months or 1 year. Specimens were submitted to µTBS using EZ test machine at a crosshead speed of 1.0 mm/min. Failure mode was examined by SEM. Data from µTBS were submitted to split plot two-way ANOVA and Tukey’s HSD tests (a=0.05). The µTBS (MPa) of Sd (41.2) was significantly higher than Ca (32.4) and Ci (27.2), regardless of storage. Ca and Ci after 6 months and 1 year, presented similar µTBS. Mixed and adhesive failures predominated in all groups. The highest µTBS values (48.1±9.1) were found for Sd at 24 h storage. Storage of specimens decreased the µTBS values for all conditions.


Resumo O objetivo neste estudo foi avaliar a resistência de união à microtração (RUµT) de um sistema adesivo convencional (Adper Single Bond 2 - SB) em diferentes substratos dentinários e períodos de armazenagem. Vinte e quatro blocos de dentina foram obtidos de terceiros molares hígidos e separados aleatoriamente em 3 grupos (n=8): dentina sadia (Ds), dentina afetada (Da) e dentina infectada (Di). A Da e a Di foram submetidas ao desenvolvimento biológico artificial de cárie (S. mutans). O tecido cariado amolecido foi removido usando broca esférica sob inspeção visual com a solução Caries Detector (grupo Da). Considerou-se como Di a dentina amolecida e fortemente pigmentada de vermelho e como Da, a dentina hígida e levemente pigmentada de vermelho. O sistema adesivo SB foi aplicado de acordo com as recomendações do fabricante e blocos da resina composta Z350 foram construídos (6 mm de altura). O conjunto (dente/bloco de resina) foi armazenado em água deionizada por 24 horas a 37 °C. Estes foram seccionados em palitos (1,0 mm2 de área), que foram separados aleatoriamente em 3 períodos de armazenagem: 24 horas, 6 meses e 1 ano. Os palitos foram submetidos ao ensaio de resistência de união à microtração na máquina EZ teste a uma velocidade de 1,0 mm/min. Dados de RUµT foram submetidos à Análise de Variância 2 fatores em esquema de parcela subdividida e ao teste de Tukey (a=0,05). Os valores de resistência (MPa) da Ds (41,2) foram significativamente maiores do que os da Da (32,4) e Di (27,2), independente do tempo de armazenagem. Di e Da, 6 meses e 1ano, apresentaram valores similares de resistência de união. As falhas adesivas e mistas foram predominantes para todos os grupos. Em conclusão, os maiores valores de RUµT (48,1±9,1) foram verificados para a Ds e 24 h de armazenagem. A armazenagem diminuiu os valores de RUµT para todas as condições.


Subject(s)
Dentin-Bonding Agents , Dental Caries , Dentin , Tensile Strength , In Vitro Techniques , Microscopy, Electron, Scanning , Healthcare Failure Mode and Effect Analysis , Molar, Third
18.
Braz. dent. j ; 27(6): 727-733, Nov.-Dec. 2016. graf
Article in English | LILACS | ID: biblio-828060

ABSTRACT

Abstract The aim of this study was to evaluate the effects of hydrofluoric acid (HF) concentration and previous heat treatment (PHT) on the surface morphology and micro-shear bond strength (mSBS) of a lithium disilicate glass ceramic (EMX) to resin cement. One hundred four EMX specimens were randomly assigned to two groups (n=52) according to the HF concentration: 5% and 10%. A new random distribution was made according to the PHTs (n=13): control (no PHT); previously heated HF (70 °C); previously heated EMX surface (85 °C); the combination of heated HF + heated EMX surface. The etching time was set at 20 s. All EMX blocks were silanated and received a thin layer of an unfilled resin. Five resin cement cylinders were made on each EMX surface using Tygon tubes as matrices, and then stored for 24 h at 37 °C. One random etched EMX sample from each group was analyzed using field-emission scanning electron microscopy (FE-SEM). The data were subjected to two-way ANOVA and multiple comparisons were performed using the Tukey post hoc test (a=0.05). For the control groups, 5% HF showed statistically lower mSBS values when compared to 10% HF (p<0.05). PHT increased the mSBS values for 5% HF, yielding statistically similar results to non-PHT 10% HF (p<0.05). FE-SEM images showed increased glassy matrix removal when PHT was applied to HF 5%, but not to the same degree as for 10% HF. PHT has the potential to improve the bond strength of 5% HF concentration on lithium disilicate glass ceramic.


Resumo O objetivo deste estudo foi avaliar os efeitos das concentrações de ácido fluorídrico (AF) e do prévio tratamento térmico (PTT) na morfologia da superfície e resistência de união ao microcisalhamento (mRUM) de uma cerâmica vítrea de dissilicato de lítio (EMX) ao cimento resinoso. Cento e quatro espécimes de EMX foram aleatoriamente distribuídos em dois grupos (n=52) de acordo com a concentração do AF: 5% e 10%. Os espécimes foram novamente distribuídos de forma aleatória de acordo com o PTT (n=13): controle (sem PTT); AF previamente aquecido (70 °C); superfície do EMX previamente aquecida (85 °C); combinação entre AF e EMX aquecidos. O tempo de condicionamento foi fixado em 20 s. Todos os espécimes de EMX foram silanizados e receberam a aplicação de uma fina camada de um adesivo sem carga. Cinco cilindros de cimento resinoso foram confeccionados usando tubos Tygon como matrizes e então armazenados por 24 h a 37 °C. Uma amostra condicionada de cada grupo foi aleatoriamente selecionada e analisada em um microscópio eletrônico de varredura em emissão de campo (MEVEC). Os dados foram submetidos ao teste ANOVA de dois fatores e múltiplas comparações foram feitas pelo teste de Tukey (a=0.05). Para os grupos controle, AF 5% mostrou valor de mRUM estatisticamente menor do que AF 10% (p<0.05). PTT aumentou os valores de mRUM para o AF 5%, proporcionando resultados estatisticamente similares ao grupo AF 10% controle (p<0.05). MEVEC mostrou um aumento na remoção da matriz vítrea quando o PTT foi aplicado ao grupo AF 5%, no entanto esse efeito não foi visto no grupo AF 10%. O PTT tem o potencial de melhorar a resistência de união do AF 5% na cerâmica vítrea reforçada por disilicato de lítio.


Subject(s)
Ceramics , Dental Bonding , Dental Porcelain/chemistry , Hot Temperature , Hydrofluoric Acid/chemistry , Materials Testing , Microscopy, Electron, Scanning , Resin Cements
19.
Braz. dent. j ; 27(6): 734-738, Nov.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-828074

ABSTRACT

Abstract The aim of this study was to evaluate the effect of silanes, thermal cycling and acid etching on the shear bond strength (SBS) of metallic brackets to feldspathic ceramic. Feldspathic ceramic cylinders (Groups 1, 2, 5 and 6) were etched for 60 s with 10% hydrofluoric acid and Groups 3, 4, 7 and 8, without acid etching. Two layers of silane Clearfil Ceramic Primer (CCP, Groups 1 to 4) and two layers of RelyX Ceramic Primer (RCP, groups 5 to 8) were applied and dried for 60 s. Brackets were bonded to the cylinders with Transbond XT and light-activated for 40 s with Bluephase G2. All specimens were stored in deionized water at 37 °C for 24 h, and the specimens of groups 1, 3, 5 and 7 were submitted to 7,000 thermal cycles (5 °C/55 °C). After storage, the SBS test was performed at a crosshead speed of 1 mm/min. Data were subjected to three-way ANOVA and Tukey's post hoc test (α=0.05). The adhesive remnant index (ARI) was evaluated at 8x magnification. The SBS of CCP was significantly greater than of RCP (p<0.05), with or without thermal cycling. Thermal cycling significantly reduced the SBS (p<0.05). The groups submitted to acid etching showed significantly higher SBS than those without acid etching (p<0.05). In conclusion, thermal cycling reduced SBS for all groups. The best ceramic surface treatment for bracket bonding was achieved by acid etching and CCP silane. The ARI results showed predominance of score 0 for all groups.


Resumo O objetivo neste estudo foi avaliar o efeito de diferentes silanos, ciclagem térmica e condicionamento ácido na resistência da união ao cisalhamento (RUC) de bráquetes metálicos a cerâmica feldspática. Cilindros da cerâmica feldspática (Grupos 1, 2, 5 e 6) foram condicionados por 60 s com ácido hidrofluorídrico a 10% e os Grupos 3, 4, 7 e 8 sem condicionamento ácido. Duas camadas do silano Clearfil Ceramic Primer (CCP, Grupos 1 a 4) e duas camadas do RelyX Ceramic Primer (RCP, Grupos 5 a 8) foram aplicadas e secas por 60 s. Bráquetes foram fixados aos cilindros cerâmicos usando Transbond XT e fotoativado por 40 s com Bluephase G2. Todas as amostras foram armazenadas em água deionizada a 37 °C por 24 h, sendo as amostras dos grupos 1, 3, 5 e 7 submetidas a 7.000 ciclos térmicos (5 °C/55 °C). Após a armazenagem, a RUC foi verificada a velocidade de 1 mm/min. Os dados foram submetidos à ANOVA 3 fatores e teste de Tukey post hoc (α=0,05). O Índice de Remanescente do Adesivo (IRA) foi avaliado com aumento de 8x. A RUC do CCP foi significantemente maior do que o RCP (p<0,05), com ou sem ciclagem térmica. A ciclagem térmica reduziu significantemente a RUC (p<0,05). Os grupos submetidos ao condicionamento ácido mostraram valores de RUC significantemente maiores em relação os grupos sem condicionamento ácido (p<0,05). Concluindo, a ciclagem térmica reduziu a RUC para todos os grupos. O melhor tratamento de superfície da cerâmica para colagem de bráquetes foi obtido pelo condicionamento ácido e pelo silano CCP. O IRA mostrou predominância de escore 0 para todos os grupos.


Subject(s)
Acid Etching, Dental/methods , Ceramics , Orthodontic Brackets , Dental Stress Analysis , Metals
20.
Braz. j. oral sci ; 15(2): 176-179, Apr.-June 2016. ilus
Article in English | LILACS, BBO | ID: biblio-848381

ABSTRACT

Aim: This in vitro study investigated the effect of the application of an adhesive, silane and thermal cycling (TC) on the shear bond strength (SBS) of ceramic brackets to feldspathic ceramic. Methods: 16 cylinders of feldspathic ceramic were etched with hydrofluoric acid and divided into four groups (n=4): G1 - silane, without TC; G2 ­ silane, with TC; G3 - adhesive, without TC; G4 - adhesive, with TC. One layer of silane was applied on the surface of cylinders in G1 and G2 e one layer of photo-activated adhesive Single Bond Universal was used in G3 and G4. Ceramic brackets were bonded using Transbond XT. The SBS data were subjected to two-way ANOVA and Tukey's post hoc test (α=0.05). The Adhesive Remnant Index (ARI) was evaluated at 40× magnification. Results: Silane was more effective than adhesive on the SBS of the brackets to ceramic (p<0.05). TC decreased significantly the SBS values compared with the groups without TC (p<0.05). The ARI results showed predominance of score 0. Conclusions: Groups with silane showed higher SBS than groups with adhesive. TC influence significantly on the bond strength. Regarding ARI, score 0 predominated in all groups (Au)


Subject(s)
Adhesives , Analysis of Variance , Ceramics , Dentistry , Shear Strength , Silanes
SELECTION OF CITATIONS
SEARCH DETAIL